100% Valid DELL-EMC E20-375 Dumps with VCE and PDF shared by PassLeader (Question 81 – Question 100)

Latest E20-375 Dumps in VCE and PDF from PassLeader: https://www.passleader.com/e20-375.html (232 Q&As), welcome to download the latest DELL&EMC E20-375 exam dumps from PassLeader.com. PassLeader.com has the most valid E20-375 exam dumps, which will help you passing E20-375 exam easily! Both E20-375 VCE and PDF dumps are available now, 100% pass ensure.

Besides, you can download the latest PassLeader E20-375 Dumps online for FREE: https://drive.google.com/open?id=1aZ2kLYcJbpe1Kr5lhudnH5FI9gwgyV7S

QUESTION 81
A company is currently using RecoverPoint/SE in their environment. They have purchased a VMAX which will be deployed to replace the VNX splitter at one site only. What must be done before they can use the VMAX with RecoverPoint (RP)?

A.    Use RecoverPoint Deployment Manager to convert from RP/SE to RP/EX or RP/CL.
B.    Use Unisphere for RecoverPoint to convert from RP/SE to RP/EX or RP/CL.
C.    Purchase and use a VMAX at the other site.
D.    Deploy an updated splitter on the existing array that will function with the new VMAX splitter.

Answer: A

QUESTION 82
Which authentication method is available for use between the vRPA and the VNX when configuring RecoverPoint/SE with Deployment Manager?

A.    CHAP
B.    iSNS
C.    LDAP
D.    RSA

Answer: A

QUESTION 83
Which RecoverPoint product(s) may be licensed by the amount of array capacity?

A.    RecoverPoint/EX only.
B.    RecoverPoint/CL only.
C.    RecoverPoint/SE.
D.    RecoverPoint/EX and RecoverPoint/CL.

Answer: A

QUESTION 84
A customer is installing a single cluster RecoverPoint/SE environment and has decided to create a cluster of six virtual RPAs to perform RecoverPoint operations. According to EMC best practices, how many ESX hosts are needed to host the required vRPAs?

A.    2
B.    3
C.    4
D.    6

Answer: D

QUESTION 85
What is a characteristic of a full sweep?

A.    Initialization is done on all volumes in a Consistency Group.
B.    Initialization is done on specific volumes in a Consistency Group.
C.    A full sweep occurs when a user enables a disabled volume.
D.    A full sweep occurs when a user enables a disabled splitter.

Answer: A

QUESTION 86
After expanding to include an additional existing RecoverPoint cluster you use Deployment Manager to connect the clusters, but it fails. What might be the problem?

A.    New cluster has existing Consistency Group.
B.    RPAs at second cluster are not same type.
C.    Second cluster not yet added to the Repository.
D.    No splitter added to second cluster.

Answer: A

QUESTION 87
You need to define the volumes required in a RecoverPoint solution. Your environment includes VMAX arrays. Four RPAs per cluster will be deployed. How many gatekeeper volumes are required per cluster?

A.    4
B.    8
C.    16
D.    32

Answer: C

QUESTION 88
An existing RecoverPoint/CL environment consists of one cluster at the main office and two off-site DR clusters. You have been asked to expand the environment to the maximum number of DR sites using RecoverPoint. How many additional clusters could be added to this RecoverPoint Environment?

A.    2
B.    4
C.    5
D.    8

Answer: A

QUESTION 89
What user action causes a full sweep to occur?

A.    Enable a disabled Consistency Group
B.    Enable a disabled volume
C.    Enable a disabled splitter
D.    Attach a volume to a splitter

Answer: A

QUESTION 90
Which statement is true regarding vRPAs?

A.    vCenter Server is required to deploy vRPAs.
B.    The proper license must be installed before vRPA deployment.
C.    vRPAs can be connected to storage through the VNX splitter in the RecoverPoint/SE system.
D.    vRPAs are installed using Unisphere for RecoverPoint.

Answer: A

QUESTION 91
A company is currently using RecoverPoint/SE in their environment. They have purchased a VMAX which will be deployed to replace a VNX splitter at one site only. What must be done before they can use the VMAX with RecoverPoint (RP)?

A.    Obtain an updated license that will support RP/EX or RP/CL.
B.    Use Unisphere for RecoverPoint to convert from RP/SE to RP/EX or RP/CL.
C.    Purchase and use a VMAX at the other site.
D.    Deploy an updated splitter on the existing array that will function with the new VMAX splitter.

Answer: A

QUESTION 92
Which image access mode provides the quickest way to access data?

A.    Virtual Access
B.    Logged Access
C.    Direct Access
D.    Snap Access

Answer: A

QUESTION 93
A customer environment includes a two-cluster RecoverPoint/SE instance. They have a new data center 500 km away that they wish to protect with RecoverPoint. What steps are required to connect a new cluster to their existing RecoverPoint instance?

A.    Use Deployment Manager to convert the existing instance to RP/EX.
Use Deployment Manager to connect the new cluster to the existing instance.
Install RP/EX licenses for their existing arrays.
B.    Use Deployment Manager to connect the new cluster to the existing instance.
C.    Install RP/SE licenses for their existing arrays.
Install RP/SE licenses for the new cluster.
Use Deployment Manager to connect the new cluster to the existing instance.
D.    Install RP/CL licenses for their existing cluster.
Use Deployment Manager to connect the new cluster to the existing instance.

Answer: A

QUESTION 94
In a EMC RecoverPoint environment, which EMC product adds support for heterogeneous storage systems?

A.    VPLEX
B.    VNX/CX
C.    VMAX
D.    Isilon

Answer: A

QUESTION 95
Which three methods are supported for sending SYR reports to EMC?

A.    FTPS, SMTP, and ESRS.
B.    ESRS, FTP, and SMTP.
C.    SMTPS, FTPS, and ESRS.
D.    SMTP, HTTPS, and ESRS.

Answer: A

QUESTION 96
A customer is installing a new RecoverPoint environment. All RPAs have been racked, cabled, and powered on. You have chosen to automatically discover the RPAs using Deployment Manager. After running the discovery, no RPAs are found. What is the most likely cause of this issue?

A.    No DHCP server on the network.
B.    Port 443 not open on the network.
C.    RecoverPoint/SE wizard selected.
D.    RPAs not configured into a cluster.

Answer: A

QUESTION 97
A VPLEX write splitter can be shared with how many RecoverPoint clusters?

A.    5
B.    6
C.    8
D.    10

Answer: B

QUESTION 98
You are implementing a RecoverPoint solution with a VNX splitter. When manually registering the RPAs on the VNX, what is the required initiator information setting?

A.    Initiator Type: RecoverPoint Appliance.
Failover Mode: 0.
B.    Initiator Type: CLARiiON Open.
Failover Mode: 1.
C.    Initiator Type: CLARiiON Open.
Failover Mode: 4.
D.    Initiator Type: RecoverPoint Appliance.
Failover Mode: 4.

Answer: D

QUESTION 99
You are troubleshooting a RecoverPoint issue. The newly configured consistency groups cannot complete their first-time initialization. Which command would you use to diagnose the problem?

A.    detect_bottlenecks
B.    system_connectivity
C.    get_group_statistics
D.    balance_load

Answer: A

QUESTION 100
You have a customer that is replicating CRR over FC. They are experiencing dropped fiber packets. You advise the customer to collect logs and open a service call immediately. The customer logs into Site 1 RPA 1 to start the log collection for the entire RPA cluster; however, log collection fails repeatedly. Why is the customer unable to collect the logs between sites?

A.    WAN IP is configured as a private IP at each site.
B.    FC connection is down between sites.
C.    Log collection must be done at each individual RPA.
D.    Management IP is not reachable at Site 2.

Answer: A


Welcome to try PassLeader E20-375 VCE and PDF dumps: https://www.passleader.com/e20-375.html (232 Q&As)

Or, download more PassLeader E20-375 dumps for FREE: https://drive.google.com/open?id=1aZ2kLYcJbpe1Kr5lhudnH5FI9gwgyV7S