Latest E20-393 Dumps in VCE and PDF from PassLeader: https://www.passleader.com/e20-393.html (341 Q&As), welcome to download the latest DELL&EMC E20-393 exam dumps from PassLeader.com. PassLeader.com has the most valid E20-393 exam dumps, which will help you passing E20-393 exam easily! Both E20-393 VCE and PDF dumps are available now, 100% pass ensure.
Besides, you can download the latest PassLeader E20-393 Dumps online for FREE: https://drive.google.com/open?id=1PofZGA9nlirgmUYMPCSEy73DmfotnJeP
NEW QUESTION 306
What are the available file system states within an FLR-enabled file system?
A. Append-only, Locked, and Protected.
B. Not-Locked, Append-only, Locked, and Expired.
C. Append, No-append, Locked, and Protected.
D. Protected, Not-Locked, Expired, and Protected.
Answer: B
NEW QUESTION 307
What is a consideration when expanding a dynamic pool?
A. Maximum number of drives is 16 in a RAID Group.
B. Maximum number of slices in a private LUN is 256.
C. Maximum number of drives is 64 in a drive partnership group.
D. Minimum number of drives in a RAID5 (4+1) RAID Group is 5.
Answer: C
NEW QUESTION 308
What is the first step to configure asynchronous replication for a storage resource?
A. Set up management channel.
B. Configure replication session.
C. Verify replication connection.
D. Create replication interfaces.
Answer: D
NEW QUESTION 309
A storage administrator is monitoring the pool Capacity of two identical Dell EMC Unity XT systems. Each system has every LUN replicated to the other system and all replication sessions are in sync. Both systems are used for production storage. CloudIQ is receiving updates from both systems, but shows that one of them is filling up more quickly than the other. What is a possible explanation for this behavior?
A. One of the Unity XT systems is used less than the other one.
B. Dell EMC Unity Data Reduction is not identically enabled on LUNs on both systems.
C. CloudIQ is not receiving the same amount of updates from one of the two systems.
D. Dell EMC Unity Data Reduction license is not enabled on one of the two systems.
Answer: B
NEW QUESTION 310
A storage administrator has configured an SMB share with the Pool Automatic Deletion retention policy. With default settings applied, what will happen when the pool crosses 95%?
A. The Dell EMC Unity system will only delete the oldest snapshot of the configured schedule.
B. Nothing. The default setting is that no snapshots will be deleted automatically.
C. The Dell EMC Unity system will delete snapshots until 85%, pool space is reached.
D. Nothing. When the snapshot reaches 25% of the pool size, snapshots will be deleted until 20% of the pool size is reached.
Answer: C
NEW QUESTION 311
Which Dell EMC Unity XT models support Dynamic Pools?
A. Dell EMC UnityVSA storage only.
B. 380F, 480F, 680F, and 880F.
C. 380F, 480, 680F, and 880.
D. 380, 480, 680, and 880.
Answer: B
NEW QUESTION 312
A user observes a system alert that indicates an error has occurred that the user should be aware of, but does not have significant impact on the system. Which severity level is this alert?
A. Error
B. Warning
C. Information
D. Notice
Answer: B
NEW QUESTION 313
Which Dell EMC Unity XT feature(s) supports deduplicated blocks?
A. VVols
B. Snapshots only
C. Snapshots and Thin Clones
D. Thin Clones only
Answer: C
NEW QUESTION 314
What is a benefit of using VVols?
A. All VMs on a datastore are snapped simultaneously.
B. Enables backup of Dell EMC Unity file data to a tape library unit.
C. Individual VMs on a datastore can be snapped.
D. Enables the assignment of isolated, file storage partitions.
Answer: A
NEW QUESTION 315
A storage administrator wants to expand the current FAST Cache size from 1.2 TB to the maximum allowed size on a Dell EMC Unity XT 880. How many drives, and of what type, do they need to add?
A. 12 Flash 2 drives of 400 GB each
B. 10 Flash 2 drives of 400 GB each
C. 24 Flash 2 drives of 400 GB each
D. 5 Flash 2 drives of 400 GB each
Answer: A
NEW QUESTION 316
How does Dell EMC Unity XT differ from Dell EMC UnityVSA?
A. Unity XT supports asynchronous replication only.
UnityVSA supports both synchronous and asynchronous replication.
B. Unity XT supports synchronous replication over Fibre Channel.
UnityVSA supports synchronous replication over GigE.
C. Unity XT supports synchronous replication over GigE.
UnityVSA supports synchronous replication over Fibre Channel.
D. Unity XT supports both synchronous and asynchronous replication.
UnityVSA supports asynchronous replication only.
Answer: D
NEW QUESTION 317
A Windows test server ran a stress test program that generated a large amount of throughput. This resulted in performance slowdowns on production hosts sharing the same VMFS datastore. What Dell EMC Unity XT feature can the storage administrator use to prevent a re-occurrence of this problem?
A. Data Reduction
B. FAST Cache
C. File System Quotas
D. Host I/O Limits
Answer: C
NEW QUESTION 318
Which Dell EMC Unity XT model(s) supports the 12 Gb/s SAS I/O module?
A. 380/380F
B. 880/880F only
C. 480/480F, 680/680F, and 880/880F
D. 680/680F and 880/880F only
Answer: A
NEW QUESTION 319
Which command can be issued from the vSphere client to configure an IP management address?
A. svc_initialize_system
B. svc_initialize_config
C. svc_initial_system
D. svc_initial_config
Answer: D
NEW QUESTION 320
Using the fan-out topology, what is the maximum number of sites a resource can be replicated to asynchronously?
A. 2
B. 4
C. 6
D. 8
Answer: B
NEW QUESTION 321
What is the default MTU value for the NAS Server interface?
A. 1280 bytes
B. 1500 bytes
C. 9000 bytes
D. 9216 bytes
Answer: B
NEW QUESTION 322
Which IP connection characteristic is used only for file-based storage configurations on Dell EMC Unity XT?
A. Link aggregation
B. VLAN tagging
C. Bandwidth throttle
D. Network latency
Answer: B
NEW QUESTION 323
What is a consideration when configuring automated software downloads on a Dell EMC Unity XT storage array?
A. VASA should be enabled.
B. One-way ESRS must be implemented on the system.
C. Firewalls should be open.
D. Two-way ESRS must be implemented on the system.
Answer: D
NEW QUESTION 324
Which storage objects support Advanced Deduplication?
A. VMFS datastores and VVols.
B. Thin LUNs and thick LUNs.
C. Thick LUNs and VVols.
D. Thin LUNs and thin VMFS datastores.
Answer: D
NEW QUESTION 325
A storage administrator configured a Hybrid Dell EMC Unity XT storage system using one pool containing SAS Flash 4 drives. They need more space, but in order to keep the additional cost as low as possible they decide to add NL-SAS drives. What is the correct way to expand the available storage?
A. Add one or more NL-SAS drives to the existing pool.
B. Add one or more RAID Groups of NL-SAS drives to the existing pool.
C. Add one or more NL-SAS drives to a separate pool.
D. Add one or more RAID Groups of NL-SAS drives to a separate pool.
Answer: C
NEW QUESTION 326
What pathing options are supported by Dell EMC Unity XT systems to provide a host with Fibre Channel access to block storage?
A. Single Path, Multipath, and Alternate Path.
B. Single Path and Multipath only.
C. Multipath only.
D. Single Path only.
Answer: B
NEW QUESTION 327
What is a benefit of Dell EMC Unity XT Series dynamic pools?
A. Reduced time to rebuild a failed drive.
B. Improved access to data resident on the drive tiers.
C. Protects written data from deletion or modification.
D. Enables throughput and bandwidth throttling.
Answer: A
NEW QUESTION 328
An administrator wants to migrate an FLR-enabled file system with DHSM-enabled from a Dell EMC VNX array to a new Dell EMC Unity XT array. What method should they use?
A. IP Replicator to replicate the file system.
B. Dell EMC Unity File Import feature.
C. IP Replicator V2 to replicate the file system.
D. CTA with Unity XT FLR-enabled FS as a tiering destination.
Answer: B
NEW QUESTION 329
What remote service is required to enable Remote Logging in the Dell EMC Unity XT system?
A. SNMPv3
B. Syslog
C. SNMPv2
D. Unisphere agent
Answer: B
NEW QUESTION 330
What is the result of enabling Data Reduction on a LUN in a Consistency Group containing three LUNs?
A. All writes to all Consistency Group LUNs will go through the Data Reduction logic.
B. Any writes to the LUN will go through the Data Reduction logic.
C. Data Reduction will be enabled on all LUNs is the Consistency Group.
D. Data Reduction and Advanced Replication will be enabled on all LUNs.
Answer: C
NEW QUESTION 331
In an asynchronous replication, what is the maximum number of replicated NAS Servers supported for the Dell EMC Unity XT 380 series?
A. 64
B. 90
C. 128
D. 256
Answer: B
NEW QUESTION 332
What features are available with Dell EMC UnityVSA?
A. Synchronous and Asynchronous Replication.
B. HOST I/O Limits and VVols.
C. FAST VP and FAST Cache.
D. Thin provisioning and Fibre Channel connectivity.
Answer: A
NEW QUESTION 333
How can an administrator disable retention on an FLR-enabled file system?
A. Use the File System Properties page in Unisphere.
B. Modify the FLR Policy on each file in the file system.
C. Modify the FLR Policy on the file system.
D. FLR cannot be disabled on this type of file system.
Answer: D
NEW QUESTION 334
An implementation engineer needs to monitor the SP Boot process. What can they use to establish a Serial over LAN connection?
A. KVT
B. puTTY
C. IPMI
D. IMT
Answer: C
NEW QUESTION 335
What is the default file system quota policy on the Dell EMC Unity XT storage array?
A. File Size
B. Blocks
C. User Quotas
D. Tree Quotas
Answer: A
NEW QUESTION 336
What benefit does the Dell EMC Unity XT UEMCLI tool provide compared to the Unisphere GUI?
A. Enables users to automate routine tasks using commands.
B. Discovering a new Dell EMC Unity array and setting up its management IP address.
C. Configuring and monitoring a Dell EMC Unity XT storage system using puTTY.
D. Enables users to run REST API calls for complex Unity deployments.
Answer: A
NEW QUESTION 337
A storage administrator wants to create datastores using VMware VASA APIs and IP networking. Which type of datastore should be used?
A. File datastore
B. Block datastore
C. VVol (file)
D. VVol (block)
Answer: D
NEW QUESTION 338
Drag and Drop
What is the correct sequence of steps to provision storage for SMB NAS clients?
NEW QUESTION 339
Drag and Drop
Match each Dell EMC tool to its respective function.
NEW QUESTION 340
Drag and Drop
What is the correct order of steps to power up a Dell EMC Unity XT storage system?
NEW QUESTION 341
……
Welcome to try PassLeader E20-393 VCE and PDF dumps: https://www.passleader.com/e20-393.html (341 Q&As)
Or, download more PassLeader E20-393 dumps for FREE: https://drive.google.com/open?id=1PofZGA9nlirgmUYMPCSEy73DmfotnJeP